C1064/C1064M – 17—Temperature of Freshly Mixed Hydraulic-Cement Concrete
This test method covers the determination of temperature of freshly mixed hydraulic-cement concrete.
1 / 10
What should be done after placing the temperature measuring device in the freshly mixed concrete?
After positioning the temperature measuring device, gently press the concrete around the device at the surface to prevent ambient air temperature from affecting the reading.
2 / 10
According to ASTM C1064, what should be done if the temperature measuring device fails verification?
If the temperature measuring device fails verification, it may be adjusted and then reverified to check if it then meets the required accuracy.
3 / 10
What is the reported accuracy of the reference temperature measuring device?
The reference temperature measuring device must be readable and accurate to ±0.2 °C at the verification points.
4 / 10
How should the thermometer be inserted into the concrete sample to ensure an accurate temperature reading?
5 / 10
What is the significance of the number following the designation C1064/C1064M in the standard?
The number following the designation indicates the year of the last revision of the standard.
6 / 10
What is the primary purpose of ASTM C1064?
ASTM C1064 provides a method for measuring the temperature of freshly mixed hydraulic-cement concrete to verify conformance to specified temperature requirements.
7 / 10
How long should the temperature measuring device remain in the concrete to obtain a reading?
The device should remain in the concrete for at least 2 minutes but not more than 5 minutes before reading the temperature.
8 / 10
According to ASTM C1064/C1064M, the temperature measuring device must be capable of accurately measuring the temperature of fresh concrete to within what range?
9 / 10
What is the minimum period that the thermometer should be left in the concrete to ensure a stable reading?
10 / 10
Within how many minutes should the temperature of freshly mixed concrete be measured after obtaining the sample?
The temperature of the freshly mixed concrete should be measured within 5 minutes of obtaining the sample to ensure accurate readings.